The Power One Aurora was made for the UK market as mid range DC Inverter, we have replaced many of this with various errors between 8-12 years old.
The E031 error is a common fault with Aurora/ABB inverters, unfortunately this is not repairable and a new inverter is needed.
Mr Solar has over 15 years in Solar PV and battery systems, we have the most up-to-date Testing and Inspection equipment for PV Panels and Inverter systems. You can now upgrade your Solar Panels with battery storage without losing your Feed in Tariff.
Fault Codes
| Error Code | Error Type | Description | |
|---|---|---|---|
| Sun Low W001 | Input voltage under threshold. Input voltage under threshold (when off) | ||
| Input OC | E001 | Input over current | |
| Input Uv W002 | Input under voltage | ||
| Input OV | E002 | Input over voltage | |
| Int. Error | E003 | No prarameters | |
| Bulk OV | E004 | Bulk over voltage | |
| Int. Error | E005 | Communication error | |
| Out OC | E006 | Output over current | |
| Int. Error | E007 | IGBT Sat | |
| Sun Low W011 | Bulk under voltage | ||
| Int. Error | E009 | Internal error | |
| Grid Fail W003 | Grid fail Wrong grid parameters | ||
| Int. Error | E010 | Bulk low | |
| Int. Error | E011 | Ramp Fail | |
| DC/DC Fail | E012 | DCDC error revealed by inverter. DCDC fault detected by inverter | |
| Wrong Mode | E013 | Wrong input setting (singed instead of dual). Wrong input setting (single instead of dual channel) | |
| Over Temp. | E014 | Over temperature. Internal temperature too high. | |
| Cap. Fault | E015 | Bulk capacitor fail. Bulk capacitor fault. | |
| Inv. Fault | E016 | Inverter fail revealed by DCDC. Inverter fault detected by DCDC. | |
| Int. Error | E017 | Start timeout | |
| Ground F. | E018 | I leak fail. Leakage current fault | |
| Int. Error | E020 | DCDC relay fail. DCDC relay fault. | |
| Int. Error | E021 | Inverter relay fail. Inverter relay fault. | |
| Int. Error | E022 | Autotest timeout | |
| Int. Error | E023 | DC injection error | |
| Grid OV W004 | Output over voltage | ||
| Grid UV W005 | Output under voltage | ||
| Grid OF W006 | Output over frequency | ||
| Grid UF W007 | Output under frequency | ||
| Z Grid HI W008 | Z grid out of range. Impedence outside range. | ||
| Int. Error | E024 | Unknown error. Internal error. | |
| E025 | Riso low (log only). Low insulation resistance (log only) | ||
| Int. Error | E026 | VRef error. Wrong reference voltage (VRef) | |
| Int. Error | E028 | Fgrid measures fault. Grid frequency (FGrid) misreading | |
| Int. Error | E029 | Zgrid measures fault | |
| Int. Error | E030 | Ileak measures fault. Leak current (ILeak) misreading | |
| Int. Error | E031 | Wrong V Measure. Voltage (V) misreading | |
| Int. Error | E032 | Wrong I Measure. Current (I) misreading | |
| Fan Fail W010 | Fan Fail (no disconnection). Fan faulty (log only) | ||
| Int. Error | E033 | Under temperature. Internal Temperature | |
| E034 | Interlock fail (not used) | ||
| E035 | Remote off. Remote power off. | ||
| E036 | Vout Avg. Average output voltage outside range | ||
| W012 | Clock battery low (no disconnection). Clock battery low (not operating) | ||
| W013 | Clock failure (no disconnection). Clock faulty (not operating) |