The Power One Aurora was made for the UK market as mid range DC Inverter, we have replaced many of this with various errors between 8-12 years old.
The E031 error is a common fault with Aurora/ABB inverters, unfortunately this is not repairable and a new inverter is needed.
Mr Solar has over 15 years in Solar PV and battery systems, we have the most up-to-date Testing and Inspection equipment for PV Panels and Inverter systems. You can now upgrade your Solar Panels with battery storage without losing your Feed in Tariff.
Fault Codes
Error Code | Error Type | Description | |
---|---|---|---|
Sun Low W001 | Input voltage under threshold. Input voltage under threshold (when off) | ||
Input OC | E001 | Input over current | |
Input Uv W002 | Input under voltage | ||
Input OV | E002 | Input over voltage | |
Int. Error | E003 | No prarameters | |
Bulk OV | E004 | Bulk over voltage | |
Int. Error | E005 | Communication error | |
Out OC | E006 | Output over current | |
Int. Error | E007 | IGBT Sat | |
Sun Low W011 | Bulk under voltage | ||
Int. Error | E009 | Internal error | |
Grid Fail W003 | Grid fail Wrong grid parameters | ||
Int. Error | E010 | Bulk low | |
Int. Error | E011 | Ramp Fail | |
DC/DC Fail | E012 | DCDC error revealed by inverter. DCDC fault detected by inverter | |
Wrong Mode | E013 | Wrong input setting (singed instead of dual). Wrong input setting (single instead of dual channel) | |
Over Temp. | E014 | Over temperature. Internal temperature too high. | |
Cap. Fault | E015 | Bulk capacitor fail. Bulk capacitor fault. | |
Inv. Fault | E016 | Inverter fail revealed by DCDC. Inverter fault detected by DCDC. | |
Int. Error | E017 | Start timeout | |
Ground F. | E018 | I leak fail. Leakage current fault | |
Int. Error | E020 | DCDC relay fail. DCDC relay fault. | |
Int. Error | E021 | Inverter relay fail. Inverter relay fault. | |
Int. Error | E022 | Autotest timeout | |
Int. Error | E023 | DC injection error | |
Grid OV W004 | Output over voltage | ||
Grid UV W005 | Output under voltage | ||
Grid OF W006 | Output over frequency | ||
Grid UF W007 | Output under frequency | ||
Z Grid HI W008 | Z grid out of range. Impedence outside range. | ||
Int. Error | E024 | Unknown error. Internal error. | |
E025 | Riso low (log only). Low insulation resistance (log only) | ||
Int. Error | E026 | VRef error. Wrong reference voltage (VRef) | |
Int. Error | E028 | Fgrid measures fault. Grid frequency (FGrid) misreading | |
Int. Error | E029 | Zgrid measures fault | |
Int. Error | E030 | Ileak measures fault. Leak current (ILeak) misreading | |
Int. Error | E031 | Wrong V Measure. Voltage (V) misreading | |
Int. Error | E032 | Wrong I Measure. Current (I) misreading | |
Fan Fail W010 | Fan Fail (no disconnection). Fan faulty (log only) | ||
Int. Error | E033 | Under temperature. Internal Temperature | |
E034 | Interlock fail (not used) | ||
E035 | Remote off. Remote power off. | ||
E036 | Vout Avg. Average output voltage outside range | ||
W012 | Clock battery low (no disconnection). Clock battery low (not operating) | ||
W013 | Clock failure (no disconnection). Clock faulty (not operating) |